Electrical & low-voltage installation · wiring only

Category 08

Fire Detection

The right detector for every space, wired by our low-voltage team to your fire alarm system.

IS 2189:2008 NBCS 2026 (SP 7) NFPA 72:2025

6 product lines

Supplied, installed & maintained

IS 2189:2008 · NBCS 2026 (SP 7) · NFPA 72:2025

Referenced standards

6 industries

Typical deployments

Product range

6 product lines

Tap "Get a quote" on any product. A specialist replies with pricing within 1 business day.

Smoke, Heat & Multi-Sensor Detectors

01

Smoke, Heat & Multi-Sensor Detectors

Right detector for every environment

Where it's used

OfficesCorridorsKitchens (heat)
Types
Optical, heat (ROR/fixed), multi-sensor
Versions
Addressable / conventional
Coverage
Up to 80 m² (smoke)
Indicator
360° LED
Standard
EN 54-5/7 referenced
Beam Smoke Detector

02

Beam Smoke Detector

Covers large open spaces with a single projected beam

Where it's used

WarehousesAtriumsAuditoriums
Range
5 – 100 m
Coverage
Up to 1,500 m²
Type
Reflective / end-to-end
Alignment
Auto-align option
Standard
EN 54-12 referenced
Aspirating Smoke Detection (VESDA)

03

Aspirating Smoke Detection (VESDA)

Very early warning by continuously sampling air

Where it's used

Data centresClean roomsHeritage sites
Sensitivity
0.005 – 20% obs/m
Coverage
Up to 2,000 m²
Pipes
Up to 4 sampling pipes
Alarm levels
Alert, Action, Fire 1, Fire 2
Standard
EN 54-20 referenced
Flame & Gas Detectors

04

Flame & Gas Detectors

UV/IR flame and fixed-point gas detection for hazardous areas

Where it's used

RefineriesGas banksChemical plants
Flame
UV/IR, IR3 multi-spectrum
Gas
LPG, methane, H₂, CO, toxic
Output
4–20 mA / relay / addressable
Housing
Ex d flameproof
Certification
ATEX / PESO referenced
Linear Heat Detection Cable

05

Linear Heat Detection Cable

Continuous heat sensing along cable trays, conveyors and tunnels

Where it's used

Cable traysConveyorsTunnels & car parks
Alarm temps
68°C, 88°C, 105°C, 180°C
Length
Up to 1,500 m per zone
Type
Digital / analogue
Interface
Monitoring module
Standard
UL 521 referenced
Battery Thermal-Runaway Detection

06

Battery Thermal-Runaway Detection

Off-gas sensing that warns before lithium batteries ignite

Where it's used

UPS roomsBESSEV charging hubs
Detection
Electrolyte off-gas (VOC / H₂)
Warning time
Minutes before thermal runaway
Mounting
Per rack / per enclosure
Output
Relay / Modbus to BMS
Use
BESS, UPS, EV charging

Where it's used

Fire Detection across industries

Corporate Offices & IT Parks

Dense occupancy, electrical load, server rooms

Healthcare & Hospitals

Non-ambulatory occupants, oxygen-rich zones

Education & Institutions

Large populations, labs and hostels

Retail, Malls & Hospitality

Transient occupants, kitchens, atria

Residential High-Rise

Vertical evacuation, basements

Government & Public Infrastructure

Public safety mandates, audit scrutiny

FAQs

Questions procurement teams ask

Consultative, not checkout

Planning a multi-site or bulk requirement?

Tell us the products and the site in 2 minutes. A Vinsafe specialist replies within one business day with pricing.