Office Fire Safety Checklist 2026: 25 Points Every Facility Manager Should Check
Updated: November 2026 2 min readBy the Vinsafe fire safety team
In short: A practical 25-point office fire safety checklist covering extinguishers, alarms, exits, electricals, training and records.
Most office fires start small: an overloaded socket, a pantry appliance, a heater left on. Whether the fire stays small depends on what you checked last month. Use this checklist every month and before any audit.
Extinguishers
- 1. Correct type for each area (ABC, CO2, clean agent, kitchen)
- 2. Within about 15 m travel distance from any point
- 3. Mounted, visible and unobstructed, with signage
- 4. Pressure in the green zone, pin and seal intact
- 5. Service tag up to date; hydro test not overdue
- 6. ISI mark present on every unit
Detection and alarm
- 7. Smoke detectors in every room, corridor and false-ceiling void where required
- 8. Heat detectors in pantries and plant rooms
- 9. Manual call points near exits, unobstructed
- 10. Fire alarm panel shows normal, no faults or disabled zones
- 11. Sounders audible in every area, including washrooms and meeting rooms
Exits and evacuation
- 12. Exit routes clear of boxes, furniture and storage
- 13. Exit doors unlocked from inside during working hours
- 14. Emergency lighting working (test by switching off mains)
- 15. Exit signs lit or photoluminescent and visible
- 16. Evacuation plan displayed on each floor
- 17. Evacuation chair or plan for people with mobility needs
Electrical and housekeeping
- 18. No overloaded sockets or daisy-chained extension boards
- 19. Electrical panels closed, labelled, with clear space in front
- 20. No combustible storage in electrical or server rooms
- 21. Pantry appliances switched off after hours
People and records
- 22. Fire wardens appointed and trained for each floor
- 23. Mock drill carried out and recorded
- 24. Staff know how to use an extinguisher (PASS method)
- 25. Maintenance register and certificates filed and up to date
Turn the checklist into a routine
Assign an owner for each section, set a monthly date and keep a signed copy. Better still, include these checks in your fire safety AMC so a trained technician does them and hands you the report.
Products mentioned in this guide

ABC Dry Powder Extinguisher
Portable Extinguishers · Multi-purpose protection for Class A, B, C & electrical fires

Smoke, Heat & Multi-Sensor Detectors
Fire Detection · Right detector for every environment

Manual Call Point & Hooter-Strobe
Fire Alarm Panels, Call Points & Voice Evacuation · Manual alarm initiation with audible and visual warning

Edge-Lit Exit Sign Light Box
Emergency & Exit Lighting · Slim illuminated exit signage visible up to 30 m
FAQs